The guid id for an object is: |
Re: How to intepret getGUID_ object_o? Well in DOORS 8.2 you get for the GUID: print (getGUID_ item fullName current Module) "\n" print (getGUID_ (current Object)) "\n" print (getURL(current Object)) "\n" // Output: // ABAAAAAAAAAAARxAAAAAAAAAAAAAAAAM // ABAAAAAAAAAAARxAAAAACAAAAAAAAAAM // doors://localhost:36677/?version=1,prodID=0,dbid=4f15504276bc42c9,container=00011c40,object=2
So the GUID is maybe something you do not want to rely on, when it comes to portable DXL. It is also not documented in the DXL help. The question would be, why you need that information? Do you need to recalculate the URL from the GUID? Module:AB:4d58be064842131f:21:21000062e3:28ffffffff:ff0000002c Object:AB:4d58be064842131f:23:21000062e3:2800000002:ff0000002c URL Moduledoors://localhost:36677/?version=2&prodID=0&view=00000001&urn=urn:telelogic::1-4d58be064842131f-M-000062e3 URL Objectdoors://localhost:36677/?version=2&prodID=0&view=00000001&urn=urn:telelogic::1-4d58be064842131f-O-2-000062e3 Module:AB:4d58be064842131f:21:21000062e3:28ffffffff:ff0000002c Object:AB:4d58be064842131f:23:21000062e3:280000007f:ff0000002c URL Moduledoors://localhost:36677/?version=2&prodID=0&view=00000002&urn=urn:telelogic::1-4d58be064842131f-M-000062e3 URL Objectdoors://localhost:36677/?version=2&prodID=0&view=00000002&urn=urn:telelogic::1-4d58be064842131f-O-127-000062e3
Mathias Mamsch, IT-QBase GmbH, Consultant for Requirement Engineering and D00RS |
Re: How to intepret getGUID_ object_o? |